Product display
contact us
Sales Hotline:
Contact Hotline
0755-83704966 18824317447
Fax:0755-83704966

E-mail:438392195@qq.com

Company address:Building 3, No. 16, Guangming Road, Shiyan street, Baoan District, Shenzhen, China
 

Product Display:

1500bi.jpg

3000bi.png

5000bi.jpg

Inverter mode (discharge)

 •Using pure sine wave output (THD<3%) IRectification mode (charging)

 •Can directly charge the battery without the need for a charger 

 •Intelligent cooling fan, automatically starts at ≥ 45 ℃ •Static loss of 22W 

 •Front panel indicator light displaying operational status 

 •Protection 

 •Input: Low voltage alarm, low voltage/overvoltage protection 

 •Output: Short circuit/overload/over temperature protection 

 •Battery over discharge protection (low voltage disconnection) 

 •Suitable for lead-acid batteries or lithium batteries •Supports RS-485 communicatio 

IRectification mode (charging)

.Can directly charge the battery without the need for a charger

.Rated voltage 220V

.Rated frequency 50/60Hz

.Maximum efficiency ≥ 91%

.Municipal power charging; MPPT charging

.UPS switching time to mains power < 20mS

Configuration

model

AC universal socket

USB interface

Control switch

Communication output wiring socket

MPPT charging interface

Municipal power charging interface

Data communication interface

Positive and negative terminal   connections

Cooling fan

 

 

1500W

2 of them

4 (supporting TYPE-C fast charging)

4 (main switch, inverter switch,   MPPT/inverter data switch, USB on)

1 (screw tightened and fixed)

1 piece

1 (Pin character socket)

1 (supports RS-485 communication)

Tighten and fix the screws

2 (Intelligent control, start when   temperature>45 , stop when   temperature 40 )

 DC INPUT PARAMETER

    1500W

3000W

5000W

input voltage

Input voltage range

Low voltage alarm

Low voltage protection

Low voltage recovery

Overvoltage protection

Rated power

AC voltage

output frequency

No load current

conversion efficiency

Output waveform

Waveform distortion degree

overload protection

Static loss

Short circuit protection

24Vdc

19~30Vdc

20Vdc

19Vdc, turn off inverter output

22Vdc

32Vdc, turn off inverter output

1500W

220V

50/60Hz

0.8A

91%

Pure sine wave

<3% (linear load)

2000W, turn off output

22W

have

24Vdc

19~30Vdc

20Vdc

19Vdc, turn off inverter output

22Vdc

32Vdc, turn off inverter output

3000W

220V

50/60Hz

0.8A

91%

Pure sine wave

<3% (linear load)

3500W, turn off output

22W

have

48Vdc

39~60Vdc

40Vdc

39Vdc, turn off inverter output

46Vdc

61Vdc, turn off inverter output

5000W

220V

50/60Hz

0.9A

91%

Pure sine wave

<3% (linear load)

5500W, turn off output

48W